Safety Management

Utility safety management is no easy job. Managing personnel, staying current on leg/reg issues, understanding record keeping processes and policy enforcement are only a few of the areas Incident Prevention provides in-depth coverage. 

The iP staff is dedicated to assisting utility safety leaders prevent job-related incidents.  Looking for insight on a particuliar subject? Send us an email and we'll assist in providing clarification / solutions!

FREE Subscription to iP Magazine. We'll send you 6 issues a year at no charge!

Friday, 18 November 2011 18:29

Basic Electric Safety

Written by 

For anyone who works at a construction site or around electrical equipment, knowing the basic dangers is an absolute must. The following Tailgate is a brief overview of the physics and hazards associated with electricity.

Basic Electrical Concepts
Current is the flow of electrical energy. It flows through a wire similar to the way water flows through a hose. A small stream of water can flow easily through a small hose, while larger flows require larger hoses. The same is true for electrical current. A small amount of current can be carried by a thin wire, but a large amount of current requires heavier wire. Current is measured in amperes, often called amps.

Voltage is electrical pressure that causes current to flow. Voltage is measured in units called volts. Voltage pushes current through a wire the same way pressure pushes water through a hose. A wire connected to a voltage source is said to be energized or hot. However, there must be enough voltage to overcome the wire’s electrical resistance before current will flow.

Resistance is the opposition that a material presents to the flow of current. It is measured in units called ohms. Current can be passed easily through some materials. Copper wire, for example, has low electrical resistance, so current flows through it easily. A material that current can flow through easily is called a conductor. Other materials, such as rubber, have high electrical resistance and are called insulators. Current cannot easily flow through an insulator.

Electrical Shock
Electrical shock is the body’s physical reaction to a significant amount of current flowing through it. The severity of the shock depends on several factors. Three main factors are the amount of current flowing through the body, the length of time that the current flows and the path that the current takes.

1. Amount of current: The more current there is flowing through the body, the stronger and more dangerous the shock. The lighting and equipment circuits at construction sites, service buildings, substations, and transmission and distribution lines carry more than enough current to produce a fatal shock.

2. Amount of time: Even a relatively small amount of current flowing for a long enough period of time can seriously injure or even kill a shock victim. The more time the body has current flowing through it, the more severe the shock.

3. Current path: The third shock severity factor is the path that the current takes through the body. It is important to note that current will only flow if there is a complete path to follow.
• If a person touches an energized conductor with one hand and another part of the same circuit with another part of his or her body, the person becomes part of the circuit. In other words, a complete path for current flow is provided, and the person will receive a shock.
• The path that current takes through a person’s body can affect the severity of a shock because some parts of the body are more vulnerable to the effects of current flow than others.
• A relatively small amount of current flow through the heart is more dangerous than a larger amount of current flow that does not pass through the heart.
• In general, current will flow through all available paths, but most of the current will flow through the path of least resistance.

Different amounts of current have different effects on the human body, and the severity of these effects increases as the level of current increases. A very small amount of current may cause only a slight tingling sensation. Increased amounts of current can cause increasing pain; loss of muscle control; breathing difficulties; ventricular fibrillation, which is uncontrolled vibration of the heart muscle; and eventually death.

basic electric safety diagram 

The most frightening aspect of these effects is that even the most severe bodily effect can be caused by current values that are much less than half an amp, and electrical equipment is often capable of supplying hundreds or thousands of amps.

About the Author: John Boyle is vice president of safety and quality for INTREN, an electric, gas and telecommunication construction company based in Union, Ill. Boyle has more than 28 years of experience, and has worked in nuclear and wind power generation and electric and gas distribution.

Read 5710 times Last modified on Friday, 18 November 2011 18:47

Subscribe-now-lg

FREE Subscription to iP Magazine.

We'll send you 6 issues a year at no charge!

Safety Management

Utility safety management is no easy job. Managing personnel, staying current on leg/reg issues, understanding record keeping processes and policy enforcement are only a few of the areas Incident Prevention provides in-depth coverage.

Read Safety Management articles

Personal Protective Equipment

OSHA requires the use of personal protective equipment (PPE) to reduce employee exposure to hazards. FR Clothing, Gloves, Head Protection, Eyewear and Protective Footwear are all PPE.  The  articles listed below discuss their proper use and maintenance. Attend iP Safety Conference & Expo to learn more about the latest PPE products.

Read Personal Protective articles

Tailgate Safety Topics

Tailgate meetings are a critical communication component of any strong utility safety program. Incident Prevention supplies the utility industry with topics for these important meetings. Each article can be printed out for use in the field or emailed to your crews.

Tailgate Safety Topic articles

Worksite Safety

Daily hazards face utility and contractor work crews. Understanding the risks involved, knowing the proper procedures, building a strong culture of open communication and constant awareness will prevent incidents. Our articles on aerial work, underground construction, grounding techniques, high-voltage risks provide utility workers a better understanding of the task at hand.  iP Safety Conferences are another great resource for understanding hazards.

Read Worksite Safety articles

Reader Profiles

Building an effective safety culture requires strong safety leadership.  The iP reader profiles features utility industry safety managers who know what it takes to overcome obstacles that brings their workers home each and every day.

Reader Profile articles

Leadership Development

As our current utility workforce retires, new utility safety leaders are coming onboard all of the time.  Incident Prevention is here to assist in the development of their leadership skills.  Managing people, understanding generational differences, building strong communications skills, establishing accountability are just a few of the subject areas covered in the magazine and at iP Safety Conferences.

Leadership Development articles

 

Equipment Operations

Safe equipment operations is required on every jobsite.  Utility work requires the use of cranes, derricks, buckets, trenchers, dozers and more.  Learn about the hazards associated with equipment operations in the articles featured below.

 Equipment Operations articles

Grounding

Grounding systems are designed so they provide the necessary safety functions. Understanding different grounding methods is critical for utility workers.  Incident Preventions relies upon industry experts to author these much needed articles.  For better insight on grounding methods used in the field you may want to attend iP Safety Conference and hear their in-depth presentations.